company news
company news / 公司新聞
[Student Questions] Selection of Water Treatment Equipment for Swimming Pool?
Step 1: Determine the cycle of swimming pool water
Cycle cycle is the required time for all pond water to be purified, filtered and disinfected once. The purpose of determining the cycle of water treatment equipment manufacturer is to limit the maximum allowable concentration of pollutants in swimming pool. Its Hangzhou water treatment equipment is determined on the basis of the operation nature of swimming pool, the number of swimmers, the area of water surface, the volume of pool water, the function of purification and filtration equipment and other factors. The following factors should be considered in determining the cycle period: (1) the type of swimming pool. For swimming pools used for competition, private use, hotels and indoors, the number of swimmers is small or relatively fixed, the quality of swimmers is better, and the personal hygiene before and after swimming is better, so the pollution degree of pool water is slower, and the reverse osmosis pure water equipment can be designed with a longer cycle. On the contrary, when the cleaning equipment of mass swimming pools or swimming pools is not perfect, because of the large number of people or poor personal hygiene treatment before swimming, the pool water pollution is faster, at this moment, a shorter cycle should be taken.
National rules for the cycle of swimming pools and aquatic paradise
Step 2: Determine the circulating flow, that is, the amount of water treated per hour.
Total swimming pool water volume (m3)cycle period (h) = treated water volume per hour (m3/h)
Step 3: Determine the type of filter, together determine the pump suction system before or after the pump suction system
1. Pre-suction system of water pump (this system is the recommendation system)
(a) The elevation on the ground of the engine room is the same as that on the horizontal plane;
B) The above ground level of the engine room is higher than that of the horizontal level.
C) The floor of the engine room is not more than 1.2 meters above the horizontal level.
2. Pump back suction system (this system is more disorderly than the former)
The floor of the machine room should be less than 4.5 meters above the horizontal level.
The above contents are based on the students'questions encountered in their practical work. For reference, if you have any questions, please communicate and correct them in time.
Author: Hangzhou Water Shield Technology Co., Ltd.
Website: http://www.zjhzsd.com/
Key words: water treatment equipment manufacturer, Hangzhou water treatment equipment, reverse osmosis pure water equipment